LAC 33:V.521
LAC 33:V.521. Specific Part II Information Requirements for Containers
Cite as La. Admin. Code tit. 33, pt. V, § 521
Except as otherwise provided in LAC 33:V.2101 owners or operators of facilities that store containers of hazardous waste must provide the following additional information:
A. a description of the containment system to demonstrate compliance with LAC 33:V.2111, show at least the following:
1. basic design parameters, dimensions, and materials of construction;
2. how the design promotes drainage or how containers are kept from contact with standing liquids in the containment system;
3. capacity of the containment system relative to the number and volume of containers to be stored;
4. provisions for preventing or managing run-on;
5. how accumulated liquids can be analyzed and removed to prevent overflow;
B. for storage areas that store containers holding wastes that do not contain free liquids, a demonstration of compliance with LAC 33:V.2111.C including:
1. test procedures and results or other documentation or information to show that the wastes do not contain free liquids; and
2. a description of how the storage area is designed or operated to drain and remove liquids or how containers are kept from contact with standing liquids;
C. sketches, drawings, or data demonstrating compliance with LAC 33:V.2113 (location of buffer zone and containers holding ignitable or reactive wastes) and LAC 33:V.2115.C (location of incompatible wastes), where applicable;
D. where incompatible wastes are stored or otherwise managed in containers, a description of the procedures used to ensure compliance with LAC 33:V.2107.A-C, and 1517.B-D; and
E. information on air emission control equipment as required in LAC 33:V.526.