A. In addition to the reporting requirements in other parts of these regulations, the licensee shall report the following events if not reported under other parts of these regulations: 1. source stuck in an unshielded position; 2. any fire or explosion in a radiation room; 3. damage to the source racks; 4. failure of the cable or drive mechanism used to move the source racks; 5. inoperability of the access control system; 6. detection of radiation source by the product exit monitor; 7. detection of radioactive contamination attributable to licensed radioactive material; 8. structural damage to the pool liner or walls; 9. water loss or leakage from the source storage pool greater than the irradiator pool design parameters submitted by the licensee or applicant; and 10. pool water conductivity exceeding 100 microsiemens per centimeter. B. The report shall include a telephone report within 24 hours, as described in LAC 33:XV.485.A, and a written report within 30 days, as described in LAC 33:XV.485.B.