310 CMR 30.688
Special Requirements for Ignitable, Reactive, and Incompatible Hazardous Wastes, and
Hazardous Wastes that are Polyhalogenated Aromatic Hydrocarbons
(1) Containers holding ignitable or reactive hazardous waste shall be located at least 15 meters
from the facility's property line.
(2)
Incompatible hazardous wastes or materials incompatible with hazardous wastes (see
310 CMR 30.561 for examples) shall not be placed in the same container unless 310 CMR
30.560(3) is complied with.
(3) Hazardous waste shall not be placed in an unwashed container that previously held waste
or material incompatible with such hazardous waste.
(4) A container holding a hazardous waste that is incompatible with any waste or other material
stored nearby in other containers or in piles, open tanks or surface impoundments shall be
separated from the other waste or other material or protected from it by means of a dike, berm,
wall, or other device.
(5) If containers holding polyhalogenated aromatic hydrocarbons are to be located or used at
the facility, the facility's contingency plan shall include the following:
(a) Procedures for responding to spills or leaks of polyhalogenated aromatic hydrocarbons
into the containment system.
(b) Procedures for removing polyhalogenated aromatic hydrocarbons from the containment
system.
(c) Procedures for repairing or replacing leaking containers.