310 CMR 43.45
Specific Guidance for the Application of Particular Conditions
(1) General. 310 CMR 43.45 provides guidance on the application of particular conditions as part
of the preparation of the Statewide Mapping and Screening Report.
(2) Modeling Capability-310 CMR 43.10. Hydrogeologic units containing faults, deeply weathered
bedrock,buried river channels and sand lenses if capable of delineation at thisstage should be screened
out.
(3) Large Existing Community Water Systems-310 CMR 43.20(1)(a). In determining the Zone III
of the supply, the drainage sub-basin of the area in which the well is located shall be delineated and
screened out.
(4) Existing Community Water Systems-310 CMR 43.20(1)(b) and 2(a). In the absence of
approved delineated Zone IIs, sites within the Interim Wellhead Protection Area [IWPA] of public
water supplies shall be delineated and screened out.
(5) Potential Productive Aquifers-310 CMR 43.20(1)(c). The Board may choose to screen out sites
located over potential productive aquifers without considering the likelihood that they will be
determined to be qualified for development.
(6) Class A Public Drinking Water Supplies-310 CMR 43.21(1)(a). In determining the watershed
of an impounded surface water supply the drainage sub-basin of the supply shall be delineated and
screened out.
(7) 100 Year Flood Plains 310 CMR 43.21(1)(c). The evaluation of flood plains should be
determined by reference to the most recently available flood profile data prepared under the National
Flood Insurance Program (NFIP), currently administered by the Federal Emergency Management
Agency. The boundary, as determined, shall be presumed accurate. This presumption may be
overcome only by reliable evidence from a registered professional engineer or other professional
competent in such matters.
(8) Coastal High Hazard Zones 310 CMR 43.21(1)(g). In determining the coastal high hazard zones
the coastal areas within the 100 year flood plain as delineated in the most recently available profile data
prepared under the NFIP and all barrier beaches should be delineated and screened out.
(9) Dams-310 CMR 43.21(1)(f). Sites located in an area which would be affected bythe failure of
a dam with a Hazard Classification Class I or Class II, as determined in accordance with 302 CMR
10.09(3), which are capable of delineation at this stage should be screened out. The downstream
inundation flood zone may be determined on the basis of records maintained by the Dam Safety
Division of the Department of Environmental Management.
(10) Interference with Monitoring 310 CMR 43.29(1)(b). Places where NationalPriorityList sites,
Resource Conservation and Recovery Act facilities, any locations of releases or sites as defined
pursuant to M.G.L. c. 21Eand the regulations promulgated thereunder, any solid waste disposalsites
as defined pursuant to M.G.L. c. 111, § 150A and the regulations promulgated thereunder or Leaking
Underground Storage Tanks as defined in M.G.L. c. 148, § 38B are identified and that are capable
of delineation at this stage should be evaluated if there is reason to believe radioactive materials or
mixed waste were used or disposed of at
those locations. The Board may chose to defer elimination of an area described hereinonthe basis of
further data on the extent to which existing potential contamination of the site willaffectthe performance
of the site and its ability to be adequately monitored.