105 CMR 120.126
Special Requirements for Issuance of Certain Specific Licenses for Radioactive Material
Uses of Sealed Sources in Industrial Radiography. In addition to the requirements set forth
in 105 CMR 120.125, a specific license for use of sealed sources in industrial radiography will
be issued if:
(1) the applicant will have an adequate program for training radiographic personnel and
submits to the Agency a schedule or description of such program which specifies the:
(a) initial training;
(b) periodic training;
(c) on-the-job training; and
(d) means to be used by the licensee to determine the radiographic personnel's
knowledge and understanding of and ability to comply with Agency regulations and
licensing requirements, and the operating and emergency procedures of the applicant.
(2) the applicant has established and submits to the Agency satisfactory written operating
and emergency procedures described in 105 CMR 120.325;
(3) the applicant will have an internal inspection system adequate to assure that 105 CMR
120.001, 120.020, 120.200, 120.300, 120.750, 120.770, license provisions, and the
applicant's operating and emergency procedures are followed by radiographic personnel; the
inspection system shall include the performance of internal inspections at intervals not to
exceed three months and the retention of records of such inspections for five years;
(4) the applicant submits to the Agency a description of the overall organizational structure
pertaining to the industrial radiography program, including specified delegations of authority
and responsibility for operation of the program;
(5) the applicant who desires to conduct his own leak tests has established adequate
procedures to be followed in testing sealed sources for possible leakage and contamination
and submits to the Agency a description of such procedures including:
(a) instrumentation to be used;
(b) method of performing tests; and
(c) pertinent experience of the individual who will perform the test.
(6) the licensee shall conduct a program for inspection and maintenance of radiographic
exposure devices and storage containers to assure proper functioning of components
important to safety.