105 CMR 120.211
Occupational Dose Limits for Adults
(A) The licensee or registrant shall control the occupational dose to individual adults, except
for planned special exposures pursuant to 105 CMR 120.216, to the following dose limits:
(1) An annual limit, which is the more limiting of:
(a) the total effective dose equivalent being equal to .05 sievert (five rems); or
(b) the sum of the deep dose equivalent and the committed dose equivalent to any
individual organ or tissue other than the lens of the eye being equal to 0.5 sievert (50
rems).
(2) The annual limits to the lens of the eye, to the skin, and to the extremities which are:
(a) a lens dose equivalent of 0.15 sievert (15 rems); and
(b) a shallow dose equivalent of 0.5 sievert (50 rems) to the skin of the whole body or
to the skin of any extremity.
(B) Doses received in excess of the annual limits, including doses received during accidents,
emergencies, and planned special exposures, shall be subtracted from the limits for planned
special exposures that the individual may receive during the current year and during the
individual's lifetime. See 105 CMR 120.216(E)(1) and (2).
(C) (1) When the external exposure is determined by measurement with an external personal
monitoring device, the deep-dose equivalent must be used in place of the effective dose
equivalent, unless the effective dose equivalent is determined by a dosimetry method
approved by the Agency. The assigned deep-dose equivalent must be for the part of the body
receiving the highest exposure. The assigned shallow-dose equivalent must be the dose
averaged over the contiguous ten square centimeters of skin receiving the highest exposure.
The deep-dose equivalent, lens-dose equivalent, and shallow-dose equivalent may be
assessed from surveys or other radiation measurements for the purpose of demonstrating
compliance with the occupational dose limits, if the individual monitoring device was not
in the region of highest potential exposure, or the results of individual monitoring are
unavailable;
(2) When a protective apron is worn while working medical fluoroscopic equipment and
monitoring is conducted as specified in 105 CMR 120.226(A)(5), the effective dose
equivalent for external radiation shall be determined as follows:
(a) When only one individual monitoring device is used and it is located at the neck
(collar) outside the protective apron, the reported deep dose equivalent shall be the
effective dose equivalent for external radiation; or
(b) When only one individual monitoring device is used and it is located at the neck
(collar) outside the protective apron, and the reported dose exceeds 25% of the limit
specified in 105 CMR 120.211(A), the reported deep dose equivalent value multiplied
by 0.3 shall be the effective dose equivalent for external radiation; or
(c) When individual monitoring devices are worn, both under the protective apron at the
waist and outside the protective apron at the neck, the effective dose equivalent for
external radiation shall be assigned the value of the sum of the deep dose equivalent
reported for the individual monitoring device located at the waist under the protective
apron multiplied by 1.5 and the deep dose equivalent reported for the individual
monitoring device located at the neck outside the protective apron multiplied by 0.04.
(D) Derived air concentration (DAC) and annual limit on intake (ALI) values are specified in
105 CMR 120.296: Appendix B, Table I and may be used to determine the individual's dose and
to demonstrate compliance with the occupational dose limits. See 105 CMR 120.267.
(E) In addition to the annual dose limits, the licensee shall limit the soluble uranium intake by
an individual to ten milligrams in a week in consideration of chemical toxicity. See footnote 3
of 105 CMR 120.296: Appendix B.
(F) The licensee or registrant shall reduce the dose that an individual may be allowed to receive
in the current year by the amount of occupational dose received while employed by any other
person during the current year. See 105 CMR 120.265(E).