105 CMR 120.213
Determination of External Dose from Airborne Radioactive Material
(A) Licensees shall, when determining the dose from airborne radioactive material, include the
contribution to the deep dose equivalent, lens dose equivalent, and shallow dose equivalent from
external exposure to the radioactive cloud. See 105 CMR 120.296: Appendix B, footnotes 1 and
2.
(B) Airborne radioactivity measurements and DAC values shall not be used as the primary
means to assess the deep dose equivalent when the airborne radioactive material includes
radionuclides other than noble gases or if the cloud of airborne radioactive material is not
relatively uniform. The determination of the deep dose equivalent to an individual shall be based
upon measurements using instruments or individual monitoring devices.