105 CMR 120.233
Use of Individual Respiratory Protection Equipment
If the licensee or registrant uses respiratory protection equipment to limit intakes pursuant
to 105 CMR 120.232:
(A) Except as provided in 105 CMR 120.233(A)(2), the licensee or registrant shall use only
respiratory protection equipment that is tested and certified by the National Institute for
Occupational Safety and Health.
(B) If the licensee or registrant wishes to use equipment that has not been tested or certified by
the National Institute for Occupational Safety, or for which there is no schedule for testing or
certification, the licensee shall submit an application to the Agency for authorization to use this
equipment, except as otherwise noted in 105 CMR 120.200. The application must include
evidence that the material and performance characteristics of the equipment are capable of
providing the proposed degree of protection under anticipated conditions of use. This must be
demonstrated either by the licensee’s or registrant’s testing or on the basis of reliable test
information;
(C) The licensee or registrant shall implement and maintain a respiratory protection program
that includes:
(1) air sampling sufficient to identify the potential hazard, permit proper equipment
selection, and estimate doses;
(2) surveys and bioassays, as necessary, to evaluate actual intakes;
(3) testing of respirators for operability user seal check for face sealing devices and
functional check for others immediately prior to each use;
(4) written procedures regarding:
(a) Monitoring, including air sampling and bioassays;
(b) Supervision and training or respirator users;
(c) Fit testing;
(d) Respirator selection;
(e) Breathing air quality;
(f) Inventory and control;
(g) Storage, issuance, maintenance, repair, testing, and quality assurance of respiratory
protection equipment;
(h) Recordkeeping; and,
(i) Limitations on periods of respirator use and relief from respirator use.
(5) determination by a physician that the individual user is medically fit to use the
respiratory protection equipment before:
(a) The initial fitting of a face sealing respirator;
(b) Before the first field use of non-face sealing respirators, and
(c) Either every 12 months thereafter, or periodically at a frequency determined by a
physician.
(6) Fit testing, with a fit factor $ 10 times the APF for negative pressure devices, and a fit
factor $ 500 for any positive pressure, continuous flow, and pressure-demand devices, before
the first field use of tight fitting, face sealing respirators and periodically thereafter at a
frequency not to exceed one year. Fit testing must be performed with the facepiece operating
in the negative pressure mode.
(D) The licensee or registrant shall advise each respirator user that the user may leave the area
at any time for relief from respirator use in the event of equipment malfunction, physical or
psychological distress, procedural or communication failure, significant deterioration of
operating conditions, or any other conditions that might require such relief.
(E) The licensee or registrant shall also consider limitations appropriate to the type and mode
of use. When selecting respiratory devices the licensee or registrant shall provide for vision
correction, adequate communication, low temperature work environments and the concurrent use
of other safety or radiological protection equipment. The licensee or registrant shall use
equipment in such a way as not to interfere with the proper operation of the respirator.
(F) Standby rescue persons are required whenever one-piece atmosphere-supplying suits, or any
combination of supplied air respiratory protection device and personnel protective equipment are
used from which an unaided individual would have difficulty extricating himself or herself. The
standby persons must be equipped with respiratory protection devices or other apparatus
appropriate for the potential hazards. The standby rescue persons shall observe or otherwise
maintain continuous communication with the workers (visual, voice, signal line, telephone,
radio, or other suitable means), and be immediately available to assist them in case of a failure
of the air supply or for any other reason that requires relief from distress. A sufficient number
of standby rescue persons must be immediately available to assist all users of this type of
equipment and to provide effective emergency rescue if needed.
(G) Atmosphere-supplying respirators must be supplied with respirable air of grade D quality
or better as defined by the Compressed Gas Association in publication G-7.1, "Commodity
Specification for Air," 1997 and included in the regulations of the Occupational Safety and
Health Administration (29 CFR 1910.134(i)(1)(ii)(A) through (E). Grade D quality air criteria
include:
(1) Oxygen content (v/v) of 19.5-23.5%;
(2) Hydrocarbon (condensed) content of 5 milligrams per cubic meter of air or less;
(3) Carbon Monoxide (CO) content of 10 ppm or less;
(4) Carbon Dioxide content of 1,000 ppm or less; and,
(5) Lack of noticeable odor
(H) The licensee shall ensure that no objects, materials or substances, such as facial hair, or any
conditions that interfere with the face-facepiece seal or valve function, and that are under the
control of the wearer, are present between the skin of the wearer’s face and the sealing surface
of a tight-fitting respirator facepiece.
(I) In estimating the dose to individuals from intake of airborne radioactive materials, the
concentration of radioactive material in the air that is inhaled when respirators are worn is
initially assumed to be the ambient concentration in air without the respiratory protection,
divided by the assigned protection factor. If the dose is later found to be greater than the
estimated dose, the corrected value must be used. If the dose is later found to be less than the
estimated dose, the corrected value may be used.