105 CMR 120.331
Surveillance
(A) During each industrial radiographic operation, a radiographer or radiographer trainee shall
maintain visual surveillance of the operation to protect against unauthorized entry into a radiation
area or high radiation area, except where the high radiation area is equipped with a control device
or alarm system as described in 105 CMR 120.227(A) or (B).
(B) Radiographic exposure devices shall not be left unattended except when in storage or
physically secured against unauthorized removal.
(C) The sealed source shall be secured and immobilized in its shielded position in the
radiographic exposure device with an appropriate locking or latching mechanism each time the
sealed source is returned to its shielded position.
(D) Notwithstanding the requirements of 105 CMR 120.243(A), High Radiation Area warnings
may be placed at the periphery of the Radiation Area, or at the perimeter of access control.