105 CMR 122.015
Non-occupational Radiofrequency Exposure Limits for the General Public
(A) No person shall knowingly operate or allow for the operation of a radiofrequency machine in a
manner that exposes or may expose any member of the public in a regularly occupied space within the
Commonwealth of Massachusetts, to a radiofrequency electromagnetic field which has a mean squared
electric or magnetic field strength or an equivalent plane wave free-space power density in excess of
the applicable Radiofrequency Exposure Limits listed in 105 CMR 122.015: Table I.
(B) In the event of scan failure or other failure in the normal parameters of the scanning operation
causing a change in angular velocity, amplitude duration, or rate of exposure, no radiofrequency
machine which emits scanned radiofrequency radiation in areas accessible to the public shall be
operated without protective measures to prevent exposure in excess of the radiofrequency exposure
limits listed in 105 CMR 122.015: Table I.
These are average values over any 0.5 hour period. See 105 CMR 122.290: Appendix A. This table does not
apply to microwave ovens, refer to 105 CMR 122.040.
See 105 CMR 122.290: Appendix A for calculation of equivalent plane wave free space power density in the
non far field region.
105 CMR 122.015: TABLE I
NON-OCCUPATIONAL RADIOFREQUENCY EXPOSURE LIMITS
FOR THE GENERAL PUBLIC1
Maximum Allowed
Maximum Allowed
Maximum Allowed
Equivalent Plane
Wave
Mean Squared
Mean Squared
Free Space
Electric Field
Magnetic Field
Power Density2
Frequency Range
Strength (V/m)
Strength (A/m)
(mW/cm )
____________________________________________________________________________
300kHz-3MHz
80,000
3MHz-30MHz
800(900/f )
0.005(900/f )
180/f
30MHz-300MHz
300MHz-1500MHz
800(f/300)
0.005(f/300)
f/1500
1500MHz-100GHz
4,000
As used in Table I:
f
= frequency in megahertz (MHz)
V
= voltage in volts
A
= current in amperes
m
= length in meters
cm
= area in square centimeters
mW = power in milliwatts
For mixed or broadband fields consisting of a number of frequencies for which different
Radiofrequency Protection Guides are listed in 105 CMR 122.015: Table I, the fraction of the
Radiofrequency Exposure Limits incurred within each frequency interval shall be determined, and the
sum of all such fractions shall not exceed unity.