105 CMR 122.290
Appendix A: Measurement Procedure for Radiofrequency Exposure
(1) Measure the existing radio-frequency radiation levels at the nearest point on the property line of
the facility owner, the point on the property line of the predicted maximum radiation from the source,
and the nearest point regularly occupied by the public.
(a) These measurements are to be made utilizing the methods described in the National Council
on Radiation Protection and Measurements (NCRP) Report No. 119 A Practical Guide to the
Determination of Human Exposure to Radiofrequency Fields or by other methods acceptable
to the Director.
(b) The applicable power density, mean squared electric or magnetic field strengths, should be
determined for public exposure pursuant to 105 CMR 122.015(A), as the average value over any
0.5 hour period. Should operation(s) be less than for 0.5 hour periods the following formula should
be used:
P = K/T
where:
P is the allowable maximum level;
K is the maximum exposure level stated in 105 CMR 122.015 Table 1; and,
T is the ratio of the exposure duration in a 0.5 hour to one half hour.
(c) In the far field region, compliance with 105 CMR 122.015 may be determined using a field
strength measuring instrument which is designed and calibrated to give a direct reading of the
equivalent plane wave free-space power density. Such direct measurement of the equivalent plane
wave free-space density measurement of the equivalent plane wave free-space density cannot be
accurately carried out in the non-far field region. To determine compliance with 105 CMR
122.015 in the non-far field region, the mean squared electric field strength and the mean squared
magnetic field strength should be measured separately. Dipoles and spectrum analyzers should be
used in multiple frequency environments. These values may then be used to calculate the equivalent
plane wave free-space power density.
(d) The effects of contributing sources of frequencies below and above frequency limits of
broadband instruments may be included by appropriate separate single instant measurements of
the contribution due to these sources. Further, levels below 20 microwatts / cm or the lowest
detectable level, whichever is lesser, should be deemed zero for further computational purposes.