105 CMR 410.220
Natural and Mechanical Ventilation
(A) Habitable rooms, and rooms with a toilet, bathtub or shower shall have:
(1) Windows, skylights, or doors through the exterior walls or roofs that can be easily
opened with a combined opening of at least 4% of the floor area of that habitable room or
room containing a toilet, bathtub or shower; or
(2) Mechanical ventilation capable of exhausting air to the outdoors.
(B) When the board of health has determined that natural ventilation is insufficient to remove
excess moisture, mechanical ventilation is required.
(C) Mechanical ventilation shall be installed and maintained in accordance with 780 CMR:
Massachusetts State Building Code.
(D) Each mechanical ventilation system shall be equipped with a readily accessible means for
shut-off, unless such system is designed to run constantly or is barometrically controlled.