115 CMR 7.07
Environmental Standards for All Site Based Services
(1)
All sites where residential supports, 24 hour site based respite supports, employment
supports and day supports are provided must meet all applicable building, sanitary, health, safety,
and zoning requirements.
(2) The environmental requirements 115 CMR of 7.07(3) through (8) shall apply to sites where
residential supports, 24 hour site based respite supports, employment supports and day supports
are provided, unless supports and services are provided in the home of the family of the
individual.
(3) All providers must assure that the sites where supports and services are provided are clean,
environmentally safe, free of vermin and obvious fire and chemical hazards, maintained in
accordance with common fire safety practices, and of sufficient size to accommodate
comfortably the number of individuals and staff it serves. Any objects or conditions that
represent a fire hazard greater than that which could be expected of ordinary household
furnishings shall not be permitted.
(4) All providers must assure that the sites used by persons with substantial mobility
impairment are barrier-free to the extent necessary to permit access to the supports, services,
personal, and common areas. A location shall be deemed to be barrier-free, in whole or part, if
it meets the applicable standards of 521 CMR: Architectural Access Board as adopted by
780 CMR: Board of Building Regulations and Standards.
(5) The following environmental requirements shall apply to sites owned or leased by providers
of residential supports, individualized home supports and 24 hour site based respite supports, and
the homes of care providers.
(a) The site shall include complete living accommodations, including its own kitchen, living
room, dining area, bedrooms, and bathrooms of typical residential design. The site shall
provide for group and individual needs, including opportunities for privacyin clearly defined
living, sleeping, and personal care spaces and areas that are accessible and available
according to individual needs to enable personal development, the development of personal
relationships, and engagement in leisure activities.
(b) The site shall provide physical comfort as well as a pleasing style of decor and an
external appearance that is typical of other homes in the vicinity, except for accommodations
that enhance accessibility for individuals.
(c) The layout of rooms shall permit ready access to common areas, with no intrusion into
private bedroom areas.
(d) The site shall provide conveniently located common storage adequate for a reasonable
amount of individual and group possessions.
(e) Major environmental controls, including those for lighting, appliances, plumbing,
windows, and shades shall be operable by and accessible to individuals.
(f) Heating and plumbing systems shall be installed and maintained for safe, healthy, and
comfortable use by the individuals supported by the provider.
(g) Heating and ventilation systems shall be adequate to maintain comfortable levels
throughout the year.
(h) All substances that are potentially dangerous in nature shall be stored separately from
food and in containers which are accurately labeled. No flammable liquids, such as gasoline,
shall be stored in the site or in spaces attached to the site.
(i) Lighting shall be adequate to meet the individual and group needs of the residents and
shall be provided in all major interior spaces, including walk-in closets and mechanical and
storage rooms.
(j) Each individual shall be provided with bedroom space adequate for sleeping, dressing,
attending to personal appearance and needs, and caring for his or her personal possessions.
The bedroom shall be of sufficient size to comfortably accommodate a bed, dresser, closet
space, and adaptive equipment if required, and to allow for an individual's privacy and
activities.
(6) The following environmental requirements shall apply to sites owned, rented or leased by
providers of residential supports, care providers, and providers of 24 hour site based respite
support:
(a) The bedroom size shall be no less than 90 to 100 square feet for a single bedroom and
130 to 144 square feet for a double bedroom.
(b) The bedroom shall be occupied by one individual; provided, however, two individuals
may share one bedroom if the two individuals, or their guardians if applicable, consent to the
sharing of the bedroom.
(c) Existing sites serving five individuals as of July 15, 2016 must have at least 1½
bathrooms. Any newly developed sites serving five individuals must have two bathrooms.
(7) The following environmental requirements shall apply to sites owned or leased by providers
of residential supports, care providers, providers of employment supports, day supports, and
providers of 24 hour site based respite supports.
(a) All sites shall have two means of egress from floors at grade level; all other floors above
grade level shall have one means of egress and one escape route serving each floor and
leading to grade. This requirement shall not apply to employment supports or day supports
when the second floor is used on an intermittent basis only. Any proven usable path to the
open air outside at grade shall be deemed acceptable as an escape route, including but not
limited to connecting doors, porches, windows within six feet of grade, ramps, fire escapes,
and balcony evacuation systems. Double cylinder dead bolt locks that require key operation
from within are prohibited on egress doors.
(b) All sites providing residential supports shall have a fire extinguisher that is operable and
that is located in the kitchen.
(c) All sites shall have smoke detectors as required by 780 CMR: Board of Building
Regulations and Standards. If more than one detector is required per site, each detector shall
be interconnected so as to activate all other detectors.
(d) All sites shall have carbon monoxide detectors as required by 780 CMR: Board of
Building Regulations and Standards.
(e) All vertical chutes (e.g., laundry chutes, dumbwaiters, heating plenums) shall be sealed
with gypsum board or some other fire retardant material.
(f) Bedroom doors are lockable unless clinically contraindicated or unless an individual,
or his or her guardian, if applicable, chooses a bedroom with access to egress and consents
to the bedroom door not having any lock.
(g) Locks on bedroom doors which do not provide access to an egress shall be permitted
only in accordance with the following:
1. The head of the provider has documentation that the lock may be easily opened from
the inside without a key and that the individual is able to unlock the door from the inside;
and
2. At all times staff carry a key or have immediate access to a key to open the door in
the event of an emergency.
(h) Bedrooms of individuals requiring hands-on physical assistance to evacuate or who have
a mobility impairment, including individuals who use a wheelchair, shall be on a floor at
grade or on a floor with a "horizontal exit," in accordance with 780 CMR: Board of State
Building Regulations and Standards.
(i) Smoking shall be permitted only under the following conditions:
1. Staff may not smoke in the homes of individuals.
2. Smoking shall be prohibited in bedrooms and at sites where employment supports or
day supports are provided.
3. Ashtrays of non-combustible material and safe design shall be provided in all areas
where smoking is permitted.
(8) A provider shall not deviate in any respect from the foregoing environmental requirements
of 115 CMR 7.07(7) as they apply to that provider, unless the provider demonstrates that the
safety needs of individuals are otherwise adequately addressed and has received approval from
the area director within its safety plan as required by 115 CMR 7.06. However, providers of 24
hour site-based respite may not deviate from any of the environmental requirements of 115 CMR
7.07(7) under any circumstances.