R 408.10033
R 408.10033 Machine controls .
Cite as Mich. Admin. Code R 408.10033
Rule 33. (1) Powered electrical equipment shall have an on-off switch .
(2) When unexpected motion would cause injury, an actuating machine control,
except for an emergency device for a powered fixed or transportable machine,
shall be guarded or located to prevent accidental actuation .
(3) Unless its function is self-evident, each operating control device shall be
identified as to its function .
(4) A powered machine that is attended by more than 1 employee shall be equipped
with an actuation device for each employee who is exposed to a point of operation
hazard. The machine shall activate only after concurrent use of all actuation devices .
(5) When unexpected motion would cause injury, precautions shall be taken to
prevent a machine from automatically restarting upon the restoration of power after a
power failure .
(6) Where a machine work station is remotely located from the machine controls,
either a red emergency stop device shall be provided at the machine work station if a
hazard exists that could cause an injury or the actuation of the controls shall require
continuous depression during the hazardous portion of the machine cycle .
(7) Equipment that is operated in series so that one piece of equipment
automatically supplies another shall be interlocked so that when any equipment in the
series is stopped for any reason, the initial stopping causes the upstream equipment to
stop if continued operation would create a hazard. Reactivation shall require a separate
positive action by the employee who initiated the stop .