R 408.10574
R 408.10574 Maintenance.
Cite as Mich. Admin. Code R 408.10574
Rule 574. (1) The following maintenance shall be performed, when required,
during the 30-day inspection:
(a) Replacement of any worn or defective parts noted during the inspections
prescribed in R 408.10572.
(b) Electrical connections shall be tightened and controller contactors and relays
shall be cleaned.
(c) Gears, shafts, bearings, brakes, and hoisting drums shall be aligned.
(2) Hoisting ropes shall be reshackled at the non-drum ends at least once every
2 years. In reshackling a rope, enough shall be cut from the end to remove damaged
or fatigued portions. The rope shall be retagged and the limit switches reset, if
necessary.
(3) Hoisting rope shall be replaced when there are 6 or more broken wires in
any 1 lay or when the wire rope becomes damaged or is in a deteriorated condition.