R 408.10575a
R 408.10575a Suspended equipment.
Cite as Mich. Admin. Code R 408.10575a
Rule 575a. (1) Each suspended unit component, except for suspension ropes and
guardrail systems, shall be capable of supporting not less than 4 times the maximum
intended live load applied or transmitted to that component.
(2) Each suspended unit component shall be constructed of materials that will
withstand anticipated weather conditions.
(3) Each suspended unit shall be provided with a load rating plate that is
conspicuously located and that states the unit weight and rated load of the suspended unit.
(4) When the suspension points on a suspended unit are not at the unit ends, the unit
shall be capable of remaining continuously stable under all conditions of use and position
of the live load and shall maintain not less than a 1.5 to 1 stability factor against unit
upset.
(5) Guide rollers, guide shoes, or building face rollers shall be provided and shall
compensate for variations in building dimensions and for minor horizontal out-of-level
variations of each suspended unit.
(6) Each working platform of a suspended unit shall be secured to the building
facade by 1 or more of the following methods or by an equivalent method that is in
compliance with the provisions of R 408.10561 and R 408.10562:
(a) Continuous.
(b) Intermittent.
(c) Button guide engagement.
(d) Angulated roping.
(e) Building face rollers.
(7) Each working platform of a suspended unit shall be provided with a guardrail
system on all sides, which shall meet the requirements of General Industry Safety and
Health Standard Part 2 “Walking-Working Surfaces,” as referenced in R 408.10509. All
of the following provisions apply to the guardrail system:
(a) The system shall consist of a top guardrail, midrail, and toeboard.
(b) The top guardrail shall be not less than 42 inches high and shall be able to
withstand not less than a 200-pound force in any downward or outward direction.
(c) The midrail shall be able to withstand not less than a 75-pound (333 n) force in
any direction.
(d) The areas between the guardrail and toeboard on the ends and outboard side, and
the area between the midrail and toeboard on the inboard side, shall be closed with a
material that is capable of withstanding a load of 100 pounds (45.4 kg.) applied
horizontally over any area of 1 square foot (.09 m2). All openings in the material shall be
small enough to prevent the passage of lifelines and potential falling objects that may be
hazardous to persons below.
(e) Toeboards shall be capable of withstanding a force of not less than 50 pounds
(222 n) applied in any direction at any point along the toeboard.
(f) Toeboards shall be not less than 4 inches in height from the top edge to the level
of the platform floor.
(g) Toeboards shall be securely fastened in place at the outermost edge of the
platform and have not more than 1/4 of an inch (1.3 cm) clearance above the platform.
(h) Toeboards shall be solid or have an opening that is not more than 1 inch (2.5 cm)
in the greatest dimension.