Rule 575e. (1) The intermittently stabilized platform shall be in compliance with the
requirements of R 408.10575b (1) to (13).
(2) Each stabilizer tie shall be equipped with a quick-connect and quick-disconnect
device that cannot be accidentally disengaged, that is for attachment to the building
anchor, and that is resistant to adverse environmental conditions.
(3) The platform shall be provided with a stopping device that will interrupt the hoist
power supply if the platform contacts a stabilizer tie during its ascent.
(4) Building face rollers shall not be placed at the anchor setting if exterior anchors
are used on the building face.
(5) Stabilizer ties that are used on intermittently stabilized platforms shall allow for
the specific attachment length that is needed to effect the predetermined angulation of the
suspended wire rope. The specific attachment length shall be maintained at all building
anchor locations.
(6) The intermittently stabilized platform shall be in continuous contact with the face
of the building during ascent and descent.
(7) The attachment and removal of stabilizer ties shall not require the horizontal
movement of the platform.
(8) The platform-mounted equipment and its suspension wire ropes shall not be
physically damaged by the loads from the stabilizer tie or its building anchor. The
platform, platform-mounted equipment, and wire ropes shall be able to withstand a load
that is not less than twice the ultimate strength of the stabilizer tie.