R 408.10579
R 408.10579 Periodic inspections and tests.
Cite as Mich. Admin. Code R 408.10579
Rule 579. (1) Related building supporting structures shall undergo periodic
inspection by a competent person at intervals of not more than 12 months.
(2) All parts of the equipment, including control systems, shall be inspected and,
where necessary, tested by a competent person at intervals specified by the manufacturer
and supplier, but not more than 12-month intervals, to determine that equipment parts are
in safe operating condition. Parts that are subject to wear, such as wire ropes, bearings,
gears, and governors, shall be inspected or tested to determine that they have not worn to
such an extent as to affect the safe operation of the installation.
(3) The owner shall keep a certification record of each inspection and test required.
The record shall include all of the following information:
(a) The date of the inspection.
(b) The signature of the person who performed the inspection.
(c) The number, or other identifier, of the building support structure and equipment
that was inspected. This certification record shall be kept readily available for review by
the director of the Michigan department of licensing and regulatory affairs or his or her
representative and by the employer.
(4) Working platforms and their components shall be inspected by the employer for
visible defects before every use and after each occurrence that could affect the platform's
structural integrity.