R 408.10586

R 408.10586 Periodic resocketing of wire rope fastenings.

Last amended: 1992Year: 2026Length: 75 wordsOfficial source

Cite as Mich. Admin. Code R 408.10586

Rule 586. (1) Hoisting ropes that utilize poured socket fastenings shall be resocketed at the non-drum ends at intervals of not more than 24 months. In resocketing the ropes, a sufficient length shall be cut from the end of the rope to remove damaged or fatigued portions. (2) Resocketed ropes shall be in compliance with the requirements of R 408.10581. (3) Limit switches that are affected by the resocketed ropes shall be reset, if necessary.