R 408.10586
R 408.10586 Periodic resocketing of wire rope fastenings.
Cite as Mich. Admin. Code R 408.10586
Rule 586. (1) Hoisting ropes that utilize poured socket fastenings shall be resocketed
at the non-drum ends at intervals of not more than 24 months. In resocketing the
ropes, a sufficient length shall be cut from the end of the rope to remove damaged or
fatigued portions.
(2) Resocketed ropes shall be in compliance with the requirements of R
408.10581.
(3) Limit switches that are affected by the resocketed ropes shall be reset, if
necessary.