R 408.10604 Definitions; H to M.
Cite as Mich. Admin. Code R 408.10604
Rule 604. (1) "Hasp and staple" means a fastening device that consists of a slotted
hinge plate and a loop (staple).
(2) "Hazardous area" means an area of a building, or portion thereof, used for
purposes that involve highly combustible, highly flammable, or explosive products or
materials which are likely to burn with extreme rapidity or which may produce poisonous
fumes or gases, including highly toxic or noxious acids, alkalines, or irritant hazards;
which cause the division of material into fine particles or dust subject to explosion or
spontaneous combustion; or which constitute a high fire hazard because of the form,
character, or volume of the material used.
(3) "Hazard of contents" means the relative danger of the start and spread of fire, the
danger of smoke or gases generated, and the danger of explosion or other occurrence
potentially endangering the lives and safety of employees in a building. Where certain
features of a building are such as to involve a hazard greater than the hazard of the
contents, the greater degree of hazard shall govern.
(4) “High hazard area” means an area inside a workplace in which operations
include high hazard materials, processes, or contents.
(5) "High hazard contents" means combustibles of a character or quantity that burn
with extreme rapidity or from which extremely poisonous fumes or explosions are to be
expected in the case of fire.
(6) "Horizontal exit" means a way of passage from a building to an area of refuge in
another building on approximately the same level or a way of passage through or around
a fire-resistant wall or fire-resistant partition to an area of refuge on approximately the
same level in the same building which affords safety from fire or smoke in the area of
escape and areas communicating therewith.
(7) "Listed” means equipment that is listed if it is of a kind mentioned in a list that is
published by a nationally recognized testing laboratory that makes periodic inspections of
the production of such equipment and that states that such equipment meets nationally
recognized standards or has been tested and found safe for use in a specified manner.
(8) "Low hazard contents" means combustibles of such low combustibility that self-
propagating fire cannot occur and that consequently the only probable danger will be
from panic, fumes, smoke, or fire from some external source.
(9) "Means of egress” also known as an “exit route” means a continuous and
unobstructed path of exit travel from any point within a workplace to a place of safety,
including refuge areas. A means of egress includes both vertical and horizontal areas
along the route of travel. A means of egress or an exit route consists of 3 separate parts
and are defined as follows:
(a) "Exit access" means that portion of a means of egress or an exit route which
leads to an exit. An example of an exit access is a corridor on the 5th floor of an office
building that leads to a 2-hour fire resistance-rated enclosed stairway.
(b) "Exit" means that portion of a means of egress or an exit route that is separated
from the area of a building from which escape is to be made by a wall, floor, door, or
other means which provides the protected path necessary to proceed with reasonable
safety to the exterior of the building. An example of an exit is a 2-hour fire resistance-
rated enclosed stairway that leads from the 5th floor of an office building to the outside of
the building.
(c) "Exit discharge" means that portion of an exit route that leads directly outside or
to a street, walkway, refuge area, public way, or open space with access to the outside.
An example of an exit discharge is a door at the bottom of a 2-hour fire resistance-rated
enclosed stairway that discharges to a place of safety outside the building.