R 408.10727
R 408.10727 Belts.
Cite as Mich. Admin. Code R 408.10727
Rule 727. (1) A belt and pulley that is 7 feet or less above the floor or platform and
that is exposed to contact must be guarded pursuant to R 408.10751 to R 408.10754. In a
power plant or power-development room, a guardrail system may be used in compliance
with General Industry Safety and Health Standard Part 2. “Walking-Working Surfaces,”
as referenced in R 408.10702.
(2) A horizontal belt more than 7 feet above the floor or platform must be guarded
for its entire length if located over a passageway or work place pursuant to R 408.10753
and figure 2 contained in subrule (5) of this rule.
(3) A passageway between horizontal belts must have a lower run guarded by a
platform that is provided with a guardrail system in compliance with General Industry
Safety and Health Standard Part 2. “Walking-Working Surfaces,” as referenced in
R 408.10702, and the upper run guarded pursuant to subrule (2) of this rule.
(4) A vertical or inclined belt running over a lower pulley more than 7 feet above the
floor or platform and located over a passageway or work place must be guarded pursuant
to subrule (2) of this rule.
(5) Figure 2 reads as follows:
FIGURE 2