R 408.10753
R 408.10753 Materials.
Cite as Mich. Admin. Code R 408.10753
Rule 753.(1) Wood guards may be used if the presence of fumes or if manufacturing
conditions cause rapid deterioration of metal guards, in construction work, and in
locations outdoors if extreme cold or extreme heat makes metal guards and railings
undesirable.
(2) Material sizes and clearances shall be pursuant to table A. See Figure 2, and
Appendices A and B.
(3) Table A reads as follows:
TABLE A
STANDARD MATERIALS AND DIMENSIONS FOR MACHINERY GUARDS
Size and Clearance of Filler Materials
Material
Clearance From
Moving Part At All
Points (Inches)
Largest Mesh
or
Opening
Allowable
B
(Inches)
Minimum
Gauge
(U.S.
Standard)
Or Thickness
Woven Wire
Under 2
2-4
4-15
3/8
1/2
2
No. 16-1/8 In.
No. 16-1/2
No. 12-2
Expanded Metal
Under 4
4-15
1/2
2
No. 18-1/2 In.
No. 13-2
Perforated
Metal
Under 4
4-15
1/2
2
No. 20-1/2 In.
No. 14-2
Sheet Metal
Under 4
4-15
- - -
No. 22
No. 22
Wood Or
Metal
Strips Crossed
}
Under 4
4-15
1/2
2
}
3/4
In.
Wood
Or
No.
16
Metal
Wood Or
Metal Strips
Not Crossed
}
Under 4
4-15
1/2 The Width
One Width
Plywood,
Plastic
Or
Equivalent
Under 4
4-15
- - -
1/4 In.
1/4 In.
Standard
Railing
Min. 15
Max. 20
- - -
- - -