R 408.11212
R 408.11212 General requirements.
Cite as Mich. Admin. Code R 408.11212
Rule 1212. (1) A mixture of fuel gas with air or oxygen shall not be permitted
except when consumed at a burner or torch.
(2) Only apparatus designed for use with fuel gas or oxygen shall be used for
welding or cutting.
(3) The total volume of acetylene used per hour shall not exceed 1/7 of the total
volume of the acetylene supply in the system.
(4) Liquid acetylene shall not be used.
(5) A cylinder to which a regulator is attached shall not be moved unless
secured to a hand truck or powered truck designed or equipped for this purpose.
(6) A cylinder valve shall be closed in all of the following situations:
(a) When the cylinder is moved.
(b) When the work is finished or is left unattended during lunch, overnight, or
for any other prolonged period.
(c) When the cylinder is empty.
(d) When the regulator is removed.
(7) Fuel gas shall not flow from a cylinder or manifold through a torch or other
device equipped with a shutoff valve unless the pressure is reduced by a regulator
attached to the cylinder or manifold.
(8) An oxygen cylinder, cylinder valve, coupling regulator, hose, and apparatus
shall be kept free from oily or greasy substances and shall not be handled with oily hands
or gloves. Precautions shall be taken to prevent a jet of oxygen from striking an
oily surface or greasy clothes or from entering a fuel, oil, or other storage tank.
(9) Oxygen shall not be used as a substitute for compressed air or for any other
use, except for welding or cutting or life support procedures.
(10) Welders shall place welding cable and other equipment so that it is clear of
passageways, ladders, and stairways or it shall be protected against damage or
hazards to an employee.
CONFINED SPACES