R 408.11421
R 408.11421 Guarding.
Cite as Mich. Admin. Code R 408.11421
Rule 1421. (1) Where a hazard exists, guards must be provided to protect an
employee from contact with moving parts where adjustments are required when a
conveyor is in operation.
(2) A lift or transfer point must have any nip point guarded and must have a means
of complying with power lockout rules.
(3) A conveyor that indexes must be guarded so that an employee will not be caught
or trapped by the sudden movement of the conveyor.
(4) A conveyor must be guarded so that an employee will not be caught or trapped
between the conveyor and a stationary or moving part.
(5) A trolley conveyor installed overhead and dipping to a work station must have a
guard or barrier in compliance with General Industry Safety and Health Standard Part 2.
“Walking-Working Surfaces,” as referenced in R 408.11402, or the area must be
designated as non-pedestrian and telltales must be hung along the portion of the conveyor
that dips to protect an employee from accidental injury.
(6) An opening for a conveyor through a floor or wall must be guarded in
compliance with General Industry Safety and Health Standard Part 2. “Walking-Working
Surfaces,” as referenced in R 408.11402.
(7) A conveyor passing over a walkway, passageway, or work area must be provided
with a pan or screen-type guard containing sides sufficient to contain any falling material
that would cause injury. The designed strength of the guard must be capable of and must
continue to withstand the maximum impact load.