R 408.11716
R 408.11716 Hoisting cables and chains.
Cite as Mich. Admin. Code R 408.11716
Rule 1716. (1) A chain and its component parts, other than alloy steel chain
having a minimum tensile strength of 125,000 pounds per square inch, shall have a
designed safety factor of not less than 5. Alloy chain shall not be used in excess of the
working load in straight tension for its size as prescribed in table 1.
(2) A hoist cable and its component parts for mobile refuse packer units shall have
a designed safety factor of not less than 2 based on the applied pull.
(3) A hoist cable shall be inspected on installation and monthly thereafter.
(4) A hoist cable shall not be used if, in any length equal to 8 diameters of the
cable, the total number of visible broken wires exceeds 10% of the total number of
wires, or if the cable shows other signs of excessive wear, corrosion, kinks or bird
caging.
(5) Where a "U" type cable clamp or clip is applied, it shall comply with table 2.
(6) The hydraulic relief valve in a cable operating system shall be set at the
manufacturer's rating and sealed.
(7) A hoist cable bent to form an eye shall be equipped with a metal thimble.
Figure for 408.11716 (1 of 2)
Note: There is only one correct method of installing wire rope clips.They should
be attached to rope ends as shown in photograph above. The base of each clip should
bear against the live, or long rope end, and the U-bolt should bear against the dead or
short rope end.
Figure for 408.11716 (2 of 2)