R 408.11835

R 408.11835 Ladders; foot-walks; stairways; escape devices.

Last amended: 2018Year: 2026Length: 220 wordsOfficial source

Cite as Mich. Admin. Code R 408.11835

Rule 1835. (1) Access to crane. Access to the car or bridge walkway shall be by a conveniently placed fixed ladder, stairs, or platform requiring no step over any gap exceeding 12 inches (30 cm). Fixed ladders shall comply with General Industry Safety and Health Standard Part 2 “Walking-Working Surfaces,” as referenced in R 408.11807. (2) A foot-walk or a cat-walk for or on a crane shall have a guardrail system as prescribed in General Industry Safety and Health Standard Part 2 “Walking-Working Surfaces,” as referenced in R 408.11807. A foot-walk shall be of rigid construction and designed to sustain a distributed load of not less than 50 pounds per square foot, and shall have an anti-slip surface. (3) An employer shall ensure that a safe method of escape is provided in case of fire or other emergency situation on a cab-operated crane. (4) A gantry crane shall have fixed ladders or stairways extending from the ground to the foot-walk or cab platform. (5) Toeboards and handrails for foot-walks. Toeboards and handrails shall comply with General Industry Safety and Health Standard Part 2 “Walking-Working Surfaces,” as referenced in R 408.11807. (6) Ladders shall be permanently and securely fastened in place and constructed in compliance with General Industry Safety and Health Standard Part 2 “Walking-Working Surfaces,” as referenced in R 408.11807.
R 408.11835: R 408.11835 Ladders; foot-walks; stairways; escape devices. | Justis AI