R 408.11861
R 408.11861 General conduct of operators.
Cite as Mich. Admin. Code R 408.11861
Rule 1861. (1) An operator, when starting on duty shall comply with both of the
following provisions:
(a) Shall not close the main switch or emergency contactor until checking to see if
anyone is on the crane and if a warning sign is on the crane, hook, or main switch.
(b) Shall test all controls, limit switches, and brakes. When a load
approaches the rated load, the operator shall test the hoisting brakes by raising the
load a few inches and applying the brakes.
(2) A hoisting limit switch on a crane or hoisting means shall not be used as an
operating control unless the crane is also equipped with a backup limit switch.
(3) A load shall not be lowered below a point where less than 2 full wraps of wire
rope remain on the hoisting drum.
(4) If there is doubt concerning the safety of a crane or hoisting means, then an
operator shall stop the crane and report the condition creating the doubt to the
supervisor.
(5) In case of power failure, an operator shall place all controllers in the "off"
position.
(6) An operator leaving a crane unattended shall land any attached load, place
the controllers in the "off" position, and open the main switch. Before closing a main
switch, an operator shall make sure all controllers are in the "off" position. The main
switch need not be opened on a pendant-controlled crane if the crane is left
unattended for short periods.
Editor's Note: An obvious error in R 408.11862 was corrected at the request of the promulgating
agency, pursuant to Section 56 of 1969 PA 306, as amended by 2000 PA 262, MCL 24.256. The rule
containing the error was published in Annual Administrative Code Supplement, 2002. The memorandum
requesting the correction was published in Michigan Register, 2013 MR 21.