R 408.12155
R 408.12155 Restriction of use.
Cite as Mich. Admin. Code R 408.12155
Rule 2155. A powered industrial truck used in an environment containing the
following substances shall be equipped as prescribed in NFPA standard 505 “Fire Safety
Standard for Powered Industrial Trucks Including Type Designations, Areas of Use,
Conversions, Maintenance, and Operations,” 1996 edition, as adopted in R 408.12111.
(a) Gases or vapors, such as, but not limited to, acetylene, hydrogen, oxygen, ether,
gasoline, naphtha, or acetone, which may be present in quantities sufficient to produce an
explosive or ignitable mixture.
(b) Combustible mixtures of dusts such as, but not limited to, metal dust, coal dust,
coke dust, grain dust, flour dust, or organic dust.
(c) Ignitable fibres such as, but not limited to, baled waste, cocoa fibre, cotton,
excelsior, kapok, or oakum.