R 408.12341
R 408.12341 Presence sensing devices.
Cite as Mich. Admin. Code R 408.12341
Rule 2341. (1) A presence sensing device shall be designed and installed so that
when the operator's hands or another part of the body disturbs the sensing field, the
downward travel of the slide is prevented or stopped. This device shall not be used as a
tripping means.
(2) Equipment shall be installed so that failure of light or photoelectric relay or
other energy source makes the press inoperative.
(3) These devices shall not, in themselves, create a physical or organic hazard to the
operator.
(4) The safety distance (Ds) from the sensing field to the point of operation shall be
greater than the distance determined by the following formula:
Ds = 63 inches/second X TS where:
Ds = minimum safety distance (inches); 63 inches/second = hand speed constant;
and
TS = stopping time of press measured when slide has completed approximately
half of the downward stroke.
(5) To protect all areas of entry to the point of operation not protected by the
presence sensing device, the partial enclosure shall be used and shall not create a pinch
point or shear hazard.