R 408.12740
R 408.12740 Double and tenoner drives.
Cite as Mich. Admin. Code R 408.12740
Rule 2740. (1) Feed chains and sprockets of double end tenoning machines shall be
completely enclosed, as prescribed in General Industry Safety Standard, Part 7 “Guards
for Power Transmission,” as referenced in R 408.12702, except for that portion of chain
used for conveying the stock.
(2) At the rear ends of frames over which feed conveyors run, sprockets and chains
shall be guarded at the sides by plates projecting beyond the periphery of sprockets and
the ends of lugs.
(3) The unloading end of the frame over which the feed conveyors run shall be
extended so the material, as it leaves the machine, will be guided to a point where the
operator cannot reach the point of operation.