R 408.13395f
R 408.13395f Lineman's body belt and pole strap systems.
Cite as Mich. Admin. Code R 408.13395f
Rule 3395f. An employer shall ensure that all lineman’s body belt and pole strap
systems meet the following tests:
(a) A dielectric test of 819.7 volts, AC, per centimeter, 25,000 volts per foot, for 3
minutes without visible deterioration.
(b) A leakage test of 98.4 volts, AC, per centimeter, 3,000 volts per foot, with a
leakage current of no more than 1 mA.
(c) A flammability test in accordance with Table F “Flammability Test.”
TABLE F
FLAMMABILITY TEST
Test Method
Criteria for Passing Test
1.
Vertically
suspend
a
19.7-inch
(500-mm) length of strapping supporting a
220.5-lb (100-kg) weight.
Any flames on the position strap
must self-extinguish.
The
positioning
strap
must
continue to support the 220.5-lb
2. Use a butane or propane burner with a
3-inch (76-mm) flame.
3. Direct the flame to an edge of the
strapping at a distance of 1 inch (25 mm).
4. Remove the flame after 5 seconds.
(100-kg) mass.
5. Wait for any flames on the positioning
strap to stop burning.