R 408.14553
R 408.14553 Furnaces.
Cite as Mich. Admin. Code R 408.14553
Rule 4553. (1) Cold or damp metal ingots shall be preheated and dried before
being added to molten metal.
(2) A furnace which needs to be tilted for discharge shall have operating
controls located outside any splash area or the operator shall be protected by a splash
shield.
(3) A furnace tender shall be not less than 2 feet from the furnace when tapping or
plugging, or the tender shall be protected by a splash shield.
(4) A gas or oil fired melting furnace installed or modified after the effective date
of this part shall be equipped with a control system which shall:
(a) Prohibit ignition and combustion until completion of a purge cycle which will
provide a minimum of 4 complete volume air changes in the ignition and combustion
chamber.
(b) Positively and immediately shut off the fuel supply in case of a pilot light or
combustion failure, or flame failure where direct ignition to the burner is used.
(5) A holding furnace installed or modified after the effective date of this part shall
be equipped as prescribed in subrule (4)(b).
(6) The requirements of subrules (4) and (5) do not apply to a gas or oil melting or
holding furnace that employs explosion resistant immersion tubes and where the
products of combustion do not discharge into a closed equipment work chamber or into a
confined space.