R 408.14931
R 408.14931 Safe operating temperatures; sling use.
Cite as Mich. Admin. Code R 408.14931
Rule 4931. (1) A wire rope sling shall not be used with loads in excess of the rated
capacities. A sling shall be used only in accordance with the manufacturer’s
recommendations.
(2) A fiber core wire rope sling of any grade shall be permanently removed from service
if it is exposed to a temperature in excess of 200 degrees Fahrenheit.
(3) When a nonfiber core wire rope sling of any grade is used at a temperature above
400 degrees Fahrenheit or below minus 60 degrees Fahrenheit, recommendations of the sling
manufacturer regarding use at that temperature shall be followed.
(4) Employers shall use only wire-rope slings that have permanently affixed and legible
identification markings as prescribed by the manufacturer and that indicate the recommended
safe working load for the type of hitch used, the angle upon which it is based, and the number
of legs if more than 1.