R 408.14944
R 408.14944 Sling use; safe operating temperatures.
Cite as Mich. Admin. Code R 408.14944
Rule 4944. (1) A metal mesh sling shall not be used to lift loads in excess of their rated
capacities.
(2) A sling shall be used only in accordance with the manufacturer’s recommendations.
(3) A metal mesh sling which is not impregnated with elastomers may be used in a
temperature range from minus 20 degrees Fahrenheit to plus 550 degrees Fahrenheit without
decreasing the working load limit.
(4) A metal mesh sling impregnated with polyvinyl chloride or neoprene may be used
only in a temperature range from zero degrees to plus 200 degrees Fahrenheit.
(5) For operations outside these temperature ranges in subrule (3) and (4) of this rule or
for metal mesh slings impregnated with other materials, the sling manufacturer's
recommendations shall be followed.