R 408.14952
R 408.14952 Splicing.
Cite as Mich. Admin. Code R 408.14952
Rule 4952. A spliced fiber rope sling shall not be used unless it has been spliced in
accordance with the following minimum requirements and in accordance with any additional
recommendations of the manufacturer:
(a) In manila rope, an eye splice shall consist of at least 3 full tucks, and short splices
shall consist of at least 6 full tucks, 3 on each side of the splice center line.
(b) In synthetic fiber rope, an eye splice shall consist of at least 4 full tucks, and short
splices shall consist of at least 8 full tucks, 4 on each side of the center line.
(c) A strand end tail shall not be trimmed flush with the surface of the rope immediately
adjacent to the full tucks. This applies to all types of fiber rope and both eye and short
splices. For fiber rope under 1 inch in diameter, the tail shall project at least 6 rope diameters
beyond the last full tuck. For fiber rope 1 inch in diameter and larger, the tail shall project at
least 6 inches beyond the last full tuck. Where a projecting tail interferes with the use of the
sling, the tail shall be tapered and spliced into the body of the rope, using at least 2 additional
tucks, which will require a tail length of approximately 6 rope diameters beyond the last full
tuck.
(d) A fiber rope sling shall have a minimum clear length of rope between eye splices
equal to 10 times the rope diameter.
(e) A knot shall not be used in lieu of a splice.
(f) A clamp not designed specifically for fiber ropes shall not be used for splicing.
(g) For any eye splice, the eye shall be of a size to provide an included angle of not
greater than 60 degrees at the splice when the eye is placed over the load or support.