R 408.15223
R 408.15223 Power control.
Cite as Mich. Admin. Code R 408.15223
Rule 5223. (1) A machine shall be equipped with an emergency stop device, red in
color, which can be activated from the operator’s work station.
(2) A machine attended by more than 1 operator shall be equipped with a control for
each operator exposed to a point of operation hazard. These controls shall be interlocked
to prevent operation until each operator activates his control.
(3) A machine control shall be designed and installed to prevent unintentional
activation by contact with objects or part of the body.
(4) A written lockout procedure shall be established by an employer and used by an
employee. A power source of any equipment to be repaired, serviced or set up shall be
locked out by each employee while doing work. Any residual pressure shall be relieved
prior to and during work.
(5) Upon power failures, provisions shall be made to prevent machines from
automatically restarting upon restoration of power.