R 408.15714
R 408.15714 Fire prevention.
Cite as Mich. Admin. Code R 408.15714
Rule 5714. (1) Smoking, open fires, or other potential sources of ignition
shall be permitted only in designated areas located at a safe distance from the
wellhead or flammable liquid storage areas. Operations or areas which constitute a fire
hazard shall be conspicuously posted with a sign, "NO SMOKING OR OPEN
FLAME."
(2) Hazardous substances shall be stored in approved containers and properly
labeled.
(3) Equipment, cellars, rig floors, and ground areas adjacent to the well shall be
kept free from oil or gas accumulations which might create or aggravate fire hazards.
(4) Oxygen, natural gas, or liquefied petroleum gas shall not be used to operate
spray guns or pneumatic tools.
(5) Combustible materials, such as oily rags and waste, shall be stored in covered
metal containers. The contents shall be disposed of daily.
(6) Gasoline-fueled engines shall be shut down before refueling operations,
unless the engine is needed for the control of the operation.