R 408.15721
R 408.15721 Construction of derricks and masts.
Cite as Mich. Admin. Code R 408.15721
Rule 5721. (1) A derrick or mast manufactured after November 21, 1979, shall have a
permanent nameplate which is attached to the structure and which indicates all of the
following information:
(a) Name of manufacturer.
(b) Model number and serial number.
(c) Rating, including maximum static hook load capacity with the number of lines.
(d) Whether guying is applicable and the recommended guying pattern. If guying
requirements do not appear on the nameplates, the derrick or mast shall be guyed as
prescribed by API SPEC 4E-1974, entitled “Specification for Drilling and Well Servicing
Structures,” which is herein adopted by reference and may be inspected at the
Department of Licensing and Regulatory Affairs, MIOSHA Standards Section, 7150
Harris Drive, P.O. Box 30643, Lansing, Michigan, 48909-8143. The specifications may
be purchased at a cost of $125.00 from IHS Global, 15 Inverness Way East, Englewood,
Colorado, 80112, USA, telephone number: 1-800-854-7179 or via the internet at website:
http://global.ihs.com.
(2) An employee qualified in procedures for raising and lowering the mast shall be in
charge of raising and lowering operations and shall do both of the following:
(a) Visually inspect the raising or lowering mechanism.
(b) Assure that all tools and materials which are not secured are removed from the
mast.
(3) Only an employee required to carry out the operation shall be allowed in or under
the mast unless it is in the fully raised or lowered position.
(4) The mast shall be level and properly positioned before raising, lowering, scoping the
structure, or tightening guylines.
(5) Before imposing any load on a derrick or mast, all required load guys shall be
properly tightened.
(6) Mast crown sheaves shall be guarded to prevent the hoisting line from being
displaced from the grooves during all operations.
(7) A derrick board or other platform shall be constructed, maintained, and adequately
secured to the structure to withstand the weight of employees and other stresses placed
upon the platform.
(8) An unguarded opening large enough to permit a person to fall through shall not exist
between the beams or main supports of the crown block.
(9) If bumperblocks are used under the crown block beam, a safety cable or strap shall
be fastened along their full length with both ends secured to the derrick.
(10) All counterweights above the rig floor, when not fully encased or running in
permanent guides, shall have a safety chain or wire rope safety line anchored to the
derrick or mast to secure them. The chain and wire rope shall be capable of sustaining the
drop load and shall limit the drop counterweight to not less than 7 feet from the floor.
(11) Load-bearing hydraulic jacks shall have a safety lock device, double valves, or the
equivalent..
(12) A derrick, mast, and auxiliary parts shall be maintained in a safe condition.