R 408.15825
R 408.15825 Controls.
Cite as Mich. Admin. Code R 408.15825
Rule 5825. (1) All of the following information shall be clearly marked in a
permanent manner on each aerial work platform:
(a) Special workings, cautions, or restrictions necessary for operation.
(b) Rated work load.
(c) A clear statement if the aerial work platform is electrically insulated.
(2) Directional controls shall be in compliance with all of the following provisions:
(a) Be of the type that will automatically return to the off or neutral position when
released.
(b) Be protected against inadvertent operation.
(c) Be clearly marked as to their intended function.
(3) An overriding control shall be provided in the platform which must be
continuously activated for platform directional controls to be operational and which
automatically returns to the off position when released.
(4) Articulating, extensible boom platforms, or both, primarily designed as
personnel carriers, shall be equipped with both upper and lower controls.
(5) Upper controls shall be located within reach of the operator.
(6) Aerial work platforms shall be equipped with emergency controls at ground
level.
(7) Emergency ground level controls shall be clearly marked as to their intended
function and be capable of overriding the platform controls.
(8) Attachment points shall be provided for fall protection devices for personnel who
occupy the platform on aerial work platforms described in R 408.15802 (a) and (c). See
Figures 1 and 3.
Compiler’s Note: R 408.15825 is being revised. In addition, the proposed rule set is
correcting the rule catch line. The current catch line has unnecessary formatting that is