R 408.15914
R 408.15914 Briefings; visibility; fires; energized lines or equipment.
Cite as Mich. Admin. Code R 408.15914
Rule 5914. (1) Briefing shall be conducted prior to each day's operation and shall
set forth the plan of operation for the pilot in command and ground employees.
(2) The employer shall insure that, when visibility is reduced by dust or other
conditions, ground employees are instructed to exercise special caution to keep clear
of the main and stabilizing rotors. The employer shall also eliminate, as far as
practical, the dust or other conditions reducing the visibility.
(3) Open fires shall not be permitted in areas where they may be spread by the rotor
downwash.
(4) A helicopter, or any part of a helicopter, shall maintain the clearances
prescribed in table 1 from any energized line or equipment, unless the owner or
operator of the line assures that the line is deenergized and visibly grounded.
TABLE 1
Voltage
Clearance
50 kilovolts or less 15 feet
More than 50 kilovolts 15 feet plus .4 inch per each kilovolt over 50 kilovolts