R 408.16351
R 408.16351 Acid rooms, acid towers, and acid tanks.
Cite as Mich. Admin. Code R 408.16351
Rule 6351. (1) An employer shall ensure that the employee is provided with eye
protection, a supplied air respirator, and a personal fall protection system that meets the
requirements of General Industry Safety and Health Standard Part 33 “Personal
Protective Equipment,” as referenced in R 408.16302, during inspection, repairs or
maintenance of acid towers. The line shall be extended to an attendant stationed outside
the tower opening.
(2) Walkways, stairs, and other equipment in acid rooms, acid towers, and acid tanks
shall be inspected monthly for corrosion and replaced or repaired where any part shows a
defect affecting employee safety.
(3) Where hoops are used on acid tanks, the hoops must be made of rods rather than
flat strip stock and be inspected and maintained as prescribed in subrule (2) of this rule.
(4) Pressure tanks-accumulators shall be inspected semiannually as prescribed in the
ASME Boiler and Pressure Vessel Code, Section VIII, “Unfired Pressure Vessels,” 1989
with addenda, as adopted in R 408.16302.
(5) An employer shall ensure that when lead burning is performed within tanks,
fresh air is forced into the tanks so that fresh air will reach the face of the employee first
and the direction of the current will never be from the source of the fumes toward the
face of the employees. Supplied air respirators, such as constant-flow type, shall be
provided as required in Occupational Health Standard Part 451 “Respiratory Protection,”
as referenced in R 408.16302.