R 408.16546
R 408.16546 Calender stopping limits.
Cite as Mich. Admin. Code R 408.16546
Rule 6546. A calender, regardless of size or configuration, shall be stopped by
braking equipment within a distance, measured in inches of surface travel of the
fastest roll, of not more than 1 3/4% of the peripheral no-load surface speed of the
calender rolls as determined in feet per minute. (See figure 3)
FIGURE 3
MAXIMUM ALLOWABLE CALENDER STOPPING DISTANCES
FOR VARIOUS ROLL SPEEDS
All measurements on calenders shall be taken with the rolls running empty at
maximum operating speed. Stopping distances shall be expressed in inches of surface
travel of the fastest roll from the instant the emergency stopping device is actuated.