R 408.17463
R 408.17463 General utility ropes, life safety ropes, harnesses, and auxiliary equipment.
Cite as Mich. Admin. Code R 408.17463
Rule 7463. (1) Life safety rope, harnesses, and auxiliary equipment dedicated for
the purpose of supporting people during emergency operations or training for these
operations must be used and meet or exceed the requirements of NFPA 1983: “Standard
on Life Safety Rope and Equipment for Emergency Services,” 2001 edition, as adopted
in R 408.17405.
(2) General utility ropes must comply with the following conditions:
(a) A rope must be inspected after each use for all of the following:
(i) Externally for abrasions, cut or broken fibers, decay, burns, lack of strength,
softness, variation in size or roundness of the strands, and for mildew or mold.
(ii) Natural fiber ropes must be inspected internally annually, by separating the
strands at 3-foot intervals, for broken fibers, presence of grit, mildew or mold, color
change of the fibers, or powdering and short, loose fibers.
(b) A rope that has any of the conditions described in subdivision (a) of this subrule
must be replaced or repaired.
(c) Ropes must be stored in a dry location.