R 408.18115
R 408.18115 Power controls and motors.
Cite as Mich. Admin. Code R 408.18115
Rule 8115. (1) Provision shall be made to prevent permanently connected machinery
and equipment, other than compressors and air moving equipment used for air
conditioning and refrigeration, and fire protection and pumps, from automatically
restarting upon restoration of power after a power interruption if unexpected start up
could cause injury.
(2) A control device, except a stop button, shall be so arranged or guarded as to
prevent accidental activation where activation could cause injury.
(3) Where a hazard exists, a machine shall be equipped with an emergency stop
device, red in color, that can be activated from an operator’s work station.
(4) When a 2-hand control device is required, it shall require the concurrent use of
both hands to activate the machine or equipment. The device shall be located in a manner
to prevent bridging. Where more than 1 employee is exposed to the point of operation, a
2-hand control device shall be provided each employee and the controls shall operate
concurrently.
(5) An electric motor, control, and other electrical components used on dry
ingredient handling and storage equipment shall be dust ignition tight.