R 408.18124
R 408.18124 Mechanical dumpbins and blenders .
Cite as Mich. Admin. Code R 408.18124
Rule 8124. (1) An opening in a mechanical dumpbin or blender shall be guarded
by 1 of the following:
(a) Parallel bars not more than 3 inches apart on centers .
(b) Not less than 11-gauge wire mesh with openings not more than 3 inches in
any direction. If an employee can reach the moving parts of the machine through the
guard, then the 3-inch opening shall be reduced until the hazard is eliminated .
(2) A mechanical dumpbin and blender shall be equipped with a suction type dust
hood of such capacity as to prevent dust circulation outside the hood .
(3) Where the loading point of a manually filled mechanical dumpbin is more than
24 inches above the floor, a bag rest shall be provided .
(4) A hinged dumpbin cover shall be provided with a means to lock the cover in
the open position or shall be counterbalanced so that it cannot accidentally fall down
while the dumpbin is in operation .