R 408.18132
R 408.18132 Continuous mixers .
Cite as Mich. Admin. Code R 408.18132
Rule 8132. (1) A cover on a continuous mixer shall be interlocked to the power
source so that the agitator will not turn when the cover is open .
(2) A continuous mixer which starts automatically shall have a warning device
which shall be activated not less than 3 seconds before start-up .
(3) A continuous mixer with a permanent inlet that introduces solids or semisolids
shall be of a configuration which would not permit hands to come in contact with