R 408.40204
R 408.40204 Responsibilities; restricted zone, wall bracing system, and signage.
Cite as Mich. Admin. Code R 408.40204
Rule 204. (1) Prior to the start of masonry construction, the mason
contractor shall notify in writing the controlling contractor where and when a restricted
zone will exist. See figure 1 for a sample restricted zone plan.
(2) The mason contractor shall establish the restricted zone and the
installation of the wall bracing system and danger signs. After the wall bracing
system and danger signs have been installed in accordance with these rules, any person
including, but not limited to, a construction manager, subcontractor, general
contractor, or owner who alters or removes the wall bracing system or danger signs
shall replace them in accordance with these rules.
(3) Each employer having workers in the restricted zone shall monitor the wind
speed and evacuate employees when the limitations of these rules have been exceeded.