R 408.40211
R 408.40211 Wall bracing design.
Cite as Mich. Admin. Code R 408.40211
Rule 211. (1) A wall bracing system shall be designed by a qualified person and
capable of providing stability to the wall for a wind speed of 40 miles per hour.
(2) A wall bracing system shall be installed in accordance with 1 of the
following:
(a) A triangle wall bracing system as prescribed in R 408.40212.
(b) A bracing plan that is designed using acceptable engineering practices and
the engineering content of the mason contractors association of America, standard
practice for bracing masonry walls under construction, chapters 5 and 6 and their
commentaries, July 2001 Edition, adopted by reference in R 408.40202. Wall
bracing erection drawings/plans or calculations and specifications shall be available
at the jobsite. Bracing schemes for walls matching examples specifically outlined in
the mason contractors association of America, masonry wallbracing design handbook,
March 2003 Edition, adopted by reference in R 408.40202, satisfy these
requirements.