R 408.40713
R 408.40713 Working in confined spaces.
Cite as Mich. Admin. Code R 408.40713
Rule 713.(1) Before the start of a welding operation in a confined space, the
employer shall ensure that the atmosphere is tested and recorded. Ventilation shall be
provided and maintained in accordance with the requirements of the department of
licensing and regulatory affairs.
(2) For specific confined space rules, see Construction Safety Standard Part 35
“Confined Space in Construction.” as referenced in R 408.40709.
(3) When working in a confined space, the torch valves, the gas supply valve, and
oxygen valve outside the confined space shall be shut off during the lunch period,
overnight, or during any other prolonged period and the torch and hose shall be removed
from the confined space. Open-end fuel gas and oxygen hoses shall be immediately
removed from enclosed spaces when they are disconnected from the torch or other gas-
consuming device.
(4) When electrodes are used in a confined space and welding is suspended during
the lunch period, overnight, or during any other prolonged period, the electrode shall be
removed from the holder and the machine shall be shut off. The holders shall be placed or
protected so that they cannot make electrical contact with employees or conducting
objects.
(5) A gas cylinder or a welding machine used for welding operations in a confined
space shall be placed on the outside of the space where work is being performed.
(6) If an employee must enter a confined space through a small opening to perform
welding operations, another employee trained in rescue procedures and equipped with the
means necessary to effect a rescue shall be stationed outside the confined space in
position to watch the welder. When a safety harness and lifeline are used, they shall be
provided for as prescribed in Construction Safety Standard Part 45 “Fall Protection,” as
referenced in R 408.40709, and shall be attached to the welder's body so that his or her
body cannot be jammed in a small exit opening.