R 408.40747
R 408.40747 Maintenance of arc welding machines.
Cite as Mich. Admin. Code R 408.40747
Rule 747. (1) Spliced welding cable shall not be used within 10 feet (3.05
meters) of an arc welding machine.
(2) Equipment in need of repair that constitutes a safety hazard shall not be used
or put in use until repairs are made by a knowledgeable employee or an outside
service.
(3) Cut insulation on work and lead cable or exposed bare conductors of an arc
welding machine shall be protected by electrical tape and shall be made watertight or
the conductor shall be replaced. Splices shall be made by insulated welded joints or
pressure connectors.
(4) An arc welding machine that has become wet shall be thoroughly dried and
tested before use.
PERSONAL PROTECTIVE EQUIPMENT